Skip to content

Capteur de COT CheckPoint de Sievers

Manufacturer
Veolia
HTTS ref.
HTS-SA-0293
HTDS ref.
CAPTEUR DE COT CHECKPOINT DE SIEVERS
Capteur de COT CheckPoint de Sievers

Description

Le capteur de carbone organique total (COT) est une solution rapide pour l’échantillonnage diagnostique mais aussi une solution de dépannage pour les applications microélectroniques, pharmaceutiques et énergétiques.

Une plus grande flexibilité lorsque vous mesurez le carbone organique total à de basses concentrations !

Portable / On-Line

Key features

  • Capteur de carbone organique total
  • 2 modèles : CheckPoint Pharma et CheckPointe (applications pharmaceutiques et d’eau extra-pure)
  • On-line : surveillance continue / Portable : transport aux réseaux d’eau
  • Peu d’entretien
  • Rapidité remarquable des analyses
  • Facile d’utilisation
  • Protocoles de validation IQ/OQ/PQ fournis

Technical specifications

Outputs
Ethernet (Modbus TCP/IP), USB, plus three 4-20 mA, two alarms,
months.
English, Chinese, or Japanese
Accuracy
± 5% at 500 ppb C of sucrose2,3
Altitude
3000 meters
Humidity
90% non-condensing
download.
CheckPoint highlights
Dimensions
25,40 cm x 30,48 cm x 15,24 cm
24 V supply.
e
Dimensions H
25.40 cm (10.0 in); W: 30.48 cm (12.0 in); D: 15.24 cm (6.0 in)
key benefits
or non-pressurized sources. CheckPointe can also
Analysis Modes
On-line (average or timed); grab (with optional Vial Sampling Kit)
Vial Sampling Kit
APK 97900
except as follows
troubleshooting. The CheckPoint Pharma comes with
Power Requirements
100–240 ±10% VAC, 60 W, 50/60 Hz, or battery
Low Pressure Samples
-6.9–55 kPa (-1.0 to 8 psig) (-0.069-0.55 bar) with optional Low Pressure Sampling Kit
Weight ― CheckPoint
2.9 kg (6.4 lb)
of 0.05 to 1,000 ppb.
water changes, the CheckPoint sensor makes it
On-Line Sample Pressure
103–690 kPa (15–100 psig) (1.0–6.9 bar)
Precision (CheckPointe)
The greater of <1% RSD or 0.05 ppb for on-line measurements;
options and accessories
ordering information
Analysis Time Selectable
15 seconds to 8 hours on-line mode; 10 minutes grab mode
Checkpoint with I/O board
PRD 97100
Non-Temperature Corrected
0.023 μS/cm (43.5 Mohm-cm) to 150 μS/cm (0.00667 Mohm-cm)
Linear Range (CheckPointe)
0.05–1,000 ppb C
Pharmacopeia specifications.
e
Précision de l’instrument
± 5% quand on mesure 500 ppb C de saccharose
Weight ― Vial Sampling Kit
0.6 kg (1.3 lb)
Gamme linéaire (CheckPointe)
0,05 ppb à 1 000 ppb C
Precision (CheckPoint Pharma)
The greater of <1% RSD or 0.21 ppb for on-line measurements;
(UPW) monitoring applications.
non-ionic organics. High pressures and temperatures
Required Sample Line Flow Rate
60 mL/min (high pressure) or 1 mL/min (low pressure)
CheckPoint installation diagram
wall mounting bracket dimensions
Temperature Corrected to 25 °C
0.055 μS/cm (18.24 Mohm-cm) to 113 μS/cm (0.00885 Mohm-cm)
Linear Range (CheckPoint Pharma)
0.21–1,000 ppb C
Temperature (CheckPointe) Sample
10–60 °C (50–140 °F); Ambient: 10–40 °C (50–104 °F)
Conductivity/Resistivity Accuracy
± 2.0%3
Installation/Overvoltage Category
II
Conductivity/Resistivity Precision
± 0.5% RSD (20–40 °C or 68–104 °F)
Dimensions with Vial Sampling Kit H
25.40 cm (10.0 in); W: 34.87 cm (13.7 in); D: 15.24 cm (6.0 in)
Gamme linéaire (CheckPoint Pharma)
0,21 ppb à 1 000 ppb C
One UV lamp (6-month continuous use)
ARK 35001
Checkpoint TOC sensor ― basic model
PRD 97000
Checkpoint In-line Filter Kit (60 μm)
APK 97300
Temperature (CheckPoint Pharma) Sample
10–90 °C (50–194 °F); Ambient: 10–55 °C (50–131 °F)3
Conductivity/Resistivity Range for TOC4
Max 1.4 μS/cm or Min 0.7 M -cm from CO24
Ozone Compatibility (CheckPoint Pharma)
50 ppb O3; 200 ppb O3 for 2 hours daily
Industrial Ratings & Safety Certifications
CE, ETL listed. Conforms to UL Std. 61010-1. Certified to CSA C22.2 No. 61010-1
anytime with the new CheckPoint Pharma and
pharmaceutical manufacturers with a cost-effective
power, and other markets, has a dynamic range
uous on-line TOC monitoring to detect critical ultrapure
Conductivity/Resistivity Calibration Stability
Typically 6 months
I/O Board ― The optional I/O board has three
Pharmaceutical Industry Part Number
and stainless steel sampling tubes and a waste
40-mL Certified Sample Vials (Case of 72) HMI 90606
CheckPoint On-Line/Portable Total Organic Carbon
and flexible process monitor for process trending,
Sensor-to-Sensor Matching ― The sensors can be
• Self-contained pump for easy system suitability and
pharmaceutical Purified Water (PW) and Water for
contamination in power feed and loop UPW. Controlling
Injection (WFI) and semiconductor ultrapure water
cation conductivity can be difficult if its source is
programmable analog outputs (select from TOC, raw
Checkpoint TOC sensor ― basic model PRD 97150
Low-Pressure Sampling Kit ― This includes Teflon
Printer HMI 97050
Versatility and Convenience ― The sensors can be
e
Vial Sampling Kit ― The CheckPoint Vial Sampling
Options
calibrated to a reference TOC instrument, allowing
calibration testing
for rapid diagnostic sampling and troubleshooting.
throughout the pharmaceutical manufacturing facility
to 1,000 ppb and can measure TOC in hot or ozonat-
qualification requirements.
• The CheckPoint , which is designed to meet the
tronics manufacturers new problem-solving and
conductivity, temperature- compensated conductivity
Checkpoint with I/O board PRD 97160
ductivity measurement (Direct Conductometric). They
or Cogeneration Condensate Polish Control) ― The
provide a reliable low-cost TOC approach useful for
CheckPoint provides sensitive detection of trace organic
CheckPoint sensors can be used online for continuous
problems in real time. The CheckPoint Pharma can be
maintenance. Calibration is typically stable for six
• Display screen and documentation available in
binary input (remote start/stop), and two alarms with
e
specifications are met at 40–55 °C (104–131 °F)
conductivity accuracy is ± 2.4%, and TOC accuracy is ± 6.7% on 500 ppb C of sucrose.
• The CheckPoint Pharma has a dynamic range of 0.21
(SOP) to meet installation, operation, and performance
Measure low-level total organic carbon (TOC) anywhere,
Pharmaceutical ― The CheckPoint Pharma provides
The two CheckPoint models have the same specifications
for multi-point water monitoring, diagnostics, and
greater sensitivity requirements of the semiconductor,
diagnostic capabilities. In addition to providing contin-
(TOC) sensors. Affordable, versatile, and portable, the
screening potential trouble areas, and diagnosing
ity, UV oxidation of organics, and a final, post-UV con-
Power (UPW, Cation Conductivity Control, Makeup,
monitoring or hand-carried to any point in a water system
placed at a dedicated point of use or conveniently moved

Applications

  • Microélectroniques
  • Pharmaceutiques

HTTSystems product sheet

Download the datasheet in our colours and contact details, or read it full screen.

Request a quote

Reference HTS-SA-0293 is carried into your file. You fill in the context, an engineer takes it from there.

Request a quote

Talk to an engineer

A question about installation, consumables or compatibility before pricing? Our engineers answer from Douala.

Ask the question